11.5.3.15 dot1x reauthentication
Description
With this command, you enable the 802.1X Re-Authentication function for the selected
interface. When the function is enabled, the authenticator repeats authentication of the client
periodically,
Requirement
You are in the Interface configuration mode.
The command prompt is as follows:
cli(config-if-$$$)#
Syntax
Call the command without parameters:
dot1x reauthentication
Result
Periodic authentication is enabled for the selected interface.
Further notes
You disable the function with the no dot1x reauthentication command.
You can display the status of this function and other information with the show
dot1xcommand.
11.5.3.16 no dot1x reauthentication
Description
With this command, you disable the function that repeats the authentication of the client by
the authenticator periodically.
Requirement
You are in the Interface configuration mode.
The command prompt is as follows:
cli(config-if-$$$)#
Security and authentication
11.5 Port Based Network Access Control
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
Configuration Manual, 07/2017, C79000-G8976-C361-06 539

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XR-300WG and is the answer not in the manual?

Siemens SCALANCE XR-300WG Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XR-300WG
CategorySwitch
LanguageEnglish

Related product manuals