Syntax
Call up the command with the following parameters:
spanning-tree[mst <instance-id(1-64)>] priority <value(0-61440)>
The parameters have the following meaning:
Parameter Description Range of values / note
mst Keyword for a Multiple Spanning Tree
instance
-
instance-id Number of the instance 1 ... 64
priority Keyword for the priority -
value Value for the priority 0 ... 61440
Default: 32768
You can only change the value for the priority in the steps of 4096.
Result
The priority of the device is configured.
Further notes
You can reset the setting to the default with the no spanning-tree priority command.
You display this setting and other information with the commands that start with show
spanning-tree ....
6.3.4.11 no spanning-tree priority
Description
With this command, you reset the priority of the device back to the default value.
The default value is 32768.
Requirement
You are in the Global Configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
no spanning-tree[mst <instance-id(1-64)>]priority
Network structures
6.3 Spanning Tree
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
236 Configuration Manual, 07/2017, C79000-G8976-C361-06

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XR-300WG and is the answer not in the manual?

Siemens SCALANCE XR-300WG Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XR-300WG
CategorySwitch
LanguageEnglish

Related product manuals