The parameters have the following meaning:
Parameter Description Range of values / note
interface-type Type or speed of the interface Enter a valid interface.
interface-id Module no. and port no. of the interface
reset After resetting Link Check, the function
is restarted on the port and the statistics
are reset.
If you use the reset parameter, the re‐
set must be performed on both connec‐
tion partners within 30 s.
When you use the reset param‐
eter, loops can form temporarily
resulting in a loss of data traffic.
The loop is automatically cleared
again.
If this is not acceptable for your ap‐
plication, reset Link Check by pull‐
ing the connecting cable and plug‐
ging it in again.
For information on names of addresses and interfaces, refer to the section "Addresses and
interface names (Page 36)".
Result
Link Check is activated on the port.
Further notes
You disable the function with the no linkcheck command.
You can display the status of this function and other information with the show linkcheck
command.
With the event config command, you can configure so that you are informed of a status
change by a message.
8.4.6.2 no linkcheck
Description
With this command, you disable the Link Check function on a port.
Requirement
You are in the Redundancy configuration mode.
The command prompt is as follows:
cli(config-red)#
Syntax
Call up the command with the following parameters:
no linkcheck {<interface-type> <interface-id>}
Layer 2 management protocols
8.4 Ring redundancy and standby connection
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
Configuration Manual, 07/2017, C79000-G8976-C361-06 401

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XR-300WG and is the answer not in the manual?

Siemens SCALANCE XR-300WG Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XR-300WG
CategorySwitch
LanguageEnglish

Related product manuals