Set Up and Maintenance
9836 3521 01 135
4.5 Station Set Up
Select a Station node object on the System tab and make sure the Details window is visible to display the
parameters available for a Station.
The name entered in the Name field defines the name of the Station. It will identify the Station in cycle
data reports, etc. The name may be up to 20 characters long.
The Advanced Reject Management if… settings are described in the functional description for
Tightening, see chapter: Advanced RM Actions.
Normally the Hold Torque step stop condition (see Tightening Program chapter: Ramps & Other – Other)
is automatically disabled for all bolts when a step fail on any of the bolts involved. This is done to avoid
overheating the motors. If it is absolutely necessary the torque may be maintained also during the reject
management phase. Check the Allow hold torque also during RM checkbox to do this.