EasyManuals Logo
Home>Atlas Copco>Power Tool>PowerMACS 4000

Atlas Copco PowerMACS 4000 User Manual

Atlas Copco PowerMACS 4000
668 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #310 background imageLoading...
Page #310 background image
Tightening
310 9836 3521 01
6.5.3.3 Fail Safe Angle
Parameters: Angle
Function: Supervises the fail-safe limits for Angle, The fail safe limits are active also during the step
overshoot time.
The angle is measured either from the current position where the step is started (AS1) or
from the point where the configured Torque start level has been reached. The measured
angle must be less than the fail-safe angle limit. No check is made until the selected start
condition has been achieved.
Diagram: See Fail Safe Torque
Alarms: Angle restriction (AR)
Trace: Angle is shown as a horizontal line from step start to step stop in trace when Angle vs. Time
is selected. Fail safe limits parameters must be enabled in the trace form (see View of
trace curves).

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Atlas Copco PowerMACS 4000 and is the answer not in the manual?

Atlas Copco PowerMACS 4000 Specifications

General IconGeneral
BrandAtlas Copco
ModelPowerMACS 4000
CategoryPower Tool
LanguageEnglish

Related product manuals