B140 SERIES AND G126 SERVICE MODE
B064 Series/B140 Series/G126 4-62 SM
SC900: Miscellaneous
SC No. Symptom Possible Cause
Electrical total counter error 900 D
The total counter contains
something that is not a number.
• NVRAM incorrect type
• NVRAM defective
• NVRAM data scrambled
• Unexpected error from external source
Mechanical total counter error 901 D
The mechanical counter is not
connected.
• Mechanical total counter defective
• Mechanical total counter connector not
connected
Printer error 1 920 B
An internal application error was
detected and operation cannot
continue.
• Software defective; turn the machine
off/on, or change the controller firmware
• Insufficient memory
Printer error 2 921 B
When the application started, the
necessary font was not on the SD
card.
• Font not on the SC card
Net File function error 925 B
The NetFile file management on the
HDD cannot be used, or a NetFile
management file is corrupted and
operation cannot continue. The
HDDs are defective and they
cannot be debugged or partitioned,
so the Scan Router functions
(delivery of received faxes,
document capture, etc.), Web
services, and other network
functions cannot be used.
HDD status codes are displayed
below the SC code:
• Refer to the four procedures below
(Recovery from SC 925).
Here is a list of HDD status codes:
Display Meaning
(-1) HDD not connected
(-2) HDD not ready
(-3) No label
(-4) Partition type incorrect
(-5) Error returned during label read or check
(-6) Error returned during label read or check
(-7) “filesystem” repair failed
(-8) “filesystem” mount failed
(-9) Drive does not answer command
(-10) Internal kernel error
(-11) Size of drive is too small
(-12) Specified partition does not exist
(-13) Device file does not exist