Xerox® VersaLink® B7025/B7030/B7035 Multifunction Printer
016-352, 016-353, 016-354
Launch Issue
Status Indicator RAPs
016-352 Internal Network Initialize Fail RAP
016-352 Internal network initialization error.
Procedure
Perform the steps that follow:
1. Switch off, then switch on the machine, GP 10.
2. Reload the software, GP 4.
016-353, 016-354 IOT-Controller Communication Fail RAP
016-353 Communication cannot be established between the IOT and the ESS.
016-354 Communication cannot be established between the IIT and the controller.
Procedure
WARNING
Ensure that the electricity to the machine is switched off while performing tasks that do
not need electricity. Refer to GP 10. Disconnect the power cord. Electricity can cause
death or injury. Moving parts can cause injury.
Perform the steps that follow:
1. Switch off, then switch on the machine, GP 10.
2. Ensure that all connectors on the drive PWB, PL 1.10 Item 3 and the ESS PWB, PL 3.10
Item 6 are securely connected. Ensure all surface mounted modules on both PWBs are
securely connected.
3. Reload the software, GP 4.
4. If the fault persists, install a new components as necessary:
• ESS PWB, PL 3.10 Item 6.
• Drive PWB, PL 1.10 Item 3.