April 2017
2-287
Xerox® VersaLink® B7025/B7030/B7035 Multifunction Printer
021-210, 211, 212, 021-213
Status Indicator RAPs
Launch Issue
021-210, 211, 212 USB IC Card Reader Error RAP
021-210 USB IC card reader connection status error.
021-211 The USB IC card reader is broken.
021-212 USB IC card reader activation failure.
Procedure
WARNING
Ensure that the electricity to the machine is switched off while performing tasks that do
not need electricity. Refer to GP 10. Disconnect the power cord. Electricity can cause
death or injury. Moving parts can cause injury.
Perform the steps that follow:
1. Switch off, then switch on the machine, GP 10.
2. Check the wiring between the card reader and the machine.
3. Enter dC131. Ensure NVM value 700-885 is set correctly:
• Internal IC card reader: 0
• IC card reader (HID support): 1
4. If the fault persists, advise the customer that the card reader is faulty.
021-213 Controller Price Table Error RAP
021-213 An error in setting up EPA controller unit price table.
Procedure
WARNING
Ensure that the electricity to the machine is switched off while performing tasks that do
not need electricity. Refer to GP 10. Disconnect the power cord. Electricity can cause
death or injury. Moving parts can cause injury.
Perform the steps that follow:
1. Advise the customer to save the unit price table to a file. Then set a value between 1 and
9999999 at the location(s) where a value out of the range is set. Then save the file con
-
taining the corrected unit price table.
2. To not use the new type of subtraction system (M/C Unit-Price Table system), enter
dC131. Set the value of NVM 850-027 to 0.
3. To use the new type of subtraction system, enter dC131. Set every available unit price
(NVM values 855-xxx) to a value between 1 and 9999999. Switch off, then switch on the
machine, GP 10.
NOTE: Obtain consent from the customer as to the values to set the prices to.
4. Perform the OF2 Special Boot Modes RAP.