April 2017
4-143
Xerox® VersaLink® B7025/B7030/B7035 Multifunction Printer
REP 60.1, REP 60.2
Repairs and Adjustments
Launch Issue
REP 60.1 Document Glass
Parts List on PL 60.10
Removal
WARNING
Switch off the electricity to the machine. Refer to GP 10. Disconnect the power cord
from the customer supply while performing tasks that do not need electricity. Electricity
can cause death or injury. Moving parts can cause injury.
1. Open the DADF.
2. Remove the right plate, PL 60.10 Item 11.
3. Remove the document glass, PL 60.10 Item 9.
Replacement
1. The replacement is the reverse of the removal procedure.
2. Before tightening the two screws, align the document glass in the direction of arrow A and
the right plate in the direction of arrow B, Figure 1.
Figure 1 Alignment
REP 60.2 CCD Lens Assembly
Parts List on PL 60.10
Removal
WARNING
Switch off the electricity to the machine. Refer to GP 10. Disconnect the power cord
from the customer supply while performing tasks that do not need electricity. Electricity
can cause death or injury. Moving parts can cause injury.
1. Remove the document glass, REP 60.1.
2. Remove the lens cover assembly, PL 60.10 Item 12.
3. Move the APS sensor, Figure 1.
a. Remove two screws (1).
b. Release the harness from the retainers (2).
c. Move the APS sensors (3).
Figure 1 APS sensors