Status Indicator RAPs
Launch Issue
041-340, 041-341 Drive PWB NVM (EEPROM) Fail RAP
BSD-ON: BSD 3.1 PWB Communications (ESS PWB to Drive PWB)
041-340 NVM (EEPROM) data abnormality.
041-341 NVM (EEPROM) access error.
Initial Actions
WARNING
Ensure that the electricity to the machine is switched off while performing tasks that do
not need electricity. Refer to GP 10. Disconnect the power cord. Electricity can cause
death or injury. Moving parts can cause injury.
Fault code 041-340 Only. Enter dC131. Check that the NVM values that follow are set to 0:
• 740-016 Range Over Chain No
• 740-017 Range Over Link No
• 740-018 Range Over Chain Link
• 740-019 Range Over Value
• 740-020 Write in Progress Range Over Chain No
• 740-021 Write in Progress Range Over Link No
Procedure
Perform the steps that follow:
1. Switch off, then switch on the machine, GP 10.
2. Reload the software, GP 4.
3. dC301 NVM Initialization.
4. If the fault persists, install new components as necessary:
•Drive PWB, PL 1.10 Item 3.
• ESS PWB, PL 3.10 Item 6.
041-371 Productivity Not Set RAP
041-371 Productivity not set.
Procedure
Perform the steps that follow:
1. Switch off, then switch on the machine, GP 10.
2. If the fault persists, perform dC132.

Table of Contents

Other manuals for Xerox VersaLink B7030

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Xerox VersaLink B7030 and is the answer not in the manual?

Xerox VersaLink B7030 Specifications

General IconGeneral
BrandXerox
ModelVersaLink B7030
CategoryAll in One Printer
LanguageEnglish

Related product manuals