April 2017
2-455
Xerox® VersaLink® B7025/B7030/B7035 Multifunction Printer
057-310, 057-312, 057-311, 313, 314, 315
Status Indicator RAPs
Launch Issue
057-310, 057-312 Drive PWB Communication Fail RAP
057-310 SPI communication data abnormality between the drive PWB and the ESS PWB.
057-312 SPI communication data abnormality between the drive PWB and the ESS PWB
Procedure
Perform the 045-311, 045-396 Controller Communication Fail RAP.
057-311, 313, 314, 315 Drive PWB Fail RAP
057-311 Abnormality in the WDT circuit that monitors the SPI communication status in which
the drive PWB is mounted.
057-313 Drive PWB fuse 13 open circuit was detected.
057-314 Drive PWB fuse 14 open circuit was detected.
057-315 Drive PWB fuse 15 open circuit was detected.
Procedure
WARNING
Ensure that the electricity to the machine is switched off while performing tasks that do
not need electricity. Refer to GP 10. Disconnect the power cord. Electricity can cause
death or injury. Moving parts can cause injury.
1. Switch off, then switch on the machine, GP 10.
2. If the fault persists, install a new drive PWB, PL 1.10 Item 3.

Table of Contents

Other manuals for Xerox VersaLink B7030

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Xerox VersaLink B7030 and is the answer not in the manual?

Xerox VersaLink B7030 Specifications

General IconGeneral
BrandXerox
ModelVersaLink B7030
CategoryAll in One Printer
LanguageEnglish

Related product manuals