April 2017
2-559
Xerox® VersaLink® B7025/B7030/B7035 Multifunction Printer
124-319, 124-320
Status Indicator RAPs
Launch Issue
124-319 DC132 Error 08 RAP
124-319 Stored data mismatch. Internal control error was detected.
Procedure
WARNING
Ensure that the electricity to the machine is switched off while performing tasks that do
not need electricity. Refer to GP 10. Disconnect the power cord. Electricity can cause
death or injury. Moving parts can cause injury.
Switch off, then switch on the machine, GP 10. The fault persists.
YN
Perform SCP 5 Final Actions.
Enter dC131. Compare NVM values 700-606, 700-607 and 700-608. All three values are dif-
ferent.
YN
Install a new drive PWB, PL 1.10 Item 3 and ESS PWB, PL 3.10 Item 6.
Perform dC132. Make all three values the same.
124-320 SEEPROM Fail RAP
124-320 Write error occurred in the SEEPROM on the ESS PWB.
Procedure
WARNING
Ensure that the electricity to the machine is switched off while performing tasks that do
not need electricity. Refer to GP 10. Disconnect the power cord. Electricity can cause
death or injury. Moving parts can cause injury.
Perform the steps that follow:
1. Switch off, then switch on the machine, GP 10.
2. Ensure that all connectors on the ESS PWB, PL 3.10 Item 6 are securely connected.
Ensure all surface mounted modules are securely connected.
3. Reload the software, GP 4.
4. If the fault persists, install a new ESS PWB, PL 3.10 Item 6.