April 2017
2-567
Xerox® VersaLink® B7025/B7030/B7035 Multifunction Printer
124-350, 124-372, 373, 374
Status Indicator RAPs
Launch Issue
124-350 CRUM OEM Fail RAP
124-350 All three CRUM OEM destinations are not set (0 or different values are set).
Procedure
WARNING
Ensure that the electricity to the machine is switched off while performing tasks that do
not need electricity. Refer to GP 10. Disconnect the power cord. Electricity can cause
death or injury. Moving parts can cause injury.
Perform the steps that follow:
1. Switch off, then switch on the machine, GP 10.
2. Enter dC132 Device ID and Billing Data. Make all three product numbers the same.
3. Ensure that all connectors on the ESS PWB, PL 3.10 Item 6 are securely connected.
Ensure all surface mounted modules are securely connected.
4. Reload the software, GP 4.
5. If the fault persists, install a new ESS PWB, PL 3.10 Item 6.
124-372, 373, 374 IOT Soft Fail RAP
124-372 IOT controller software failure.
124-373 IOT manager software failure.
124-374 IOT IM device driver software failure.
Procedure
WARNING
Ensure that the electricity to the machine is switched off while performing tasks that do
not need electricity. Refer to GP 10. Disconnect the power cord. Electricity can cause
death or injury. Moving parts can cause injury.
Perform the steps that follow:
1. Switch off, then switch on the machine, GP 10.
2. Ensure that all connectors on the ESS PWB, PL 3.10 Item 6 are securely connected.
Ensure all surface mounted modules are securely connected.
3. Reload the software, GP 4.
4. Perform the OF2 Special Boot Modes RAP.