Status Indicator RAPs
Launch Issue
059-383 Warm Up Time Fail RAP
BSD-ON: BSD 10.1 Fusing Heat Control (1 of 2)
BSD-ON: BSD 10.2 Fusing Heat Control (2 of 2)
010-383 When transitioning from the wait state, the specified temperature is not reached within
the specified time.
NOTE: This fault may occur when the temperature in the installation environment is low (10
degrees C or lower).
Procedure
WARNING
Ensure that the electricity to the machine is switched off while performing tasks that do
not need electricity. Refer to GP 10. Disconnect the power cord. Electricity can cause
death or injury. Moving parts can cause injury.
Perform the steps that follow:
1. Switch off, then switch on the machine, GP 10.
2. Ensure that the fuser is installed correctly.
3. Check the drawer connector between the fuser and the main unit ( DP612) for damage.
4. Check the connections and wiring between the fuser ( DP612) and the LVPS ( P2) for an
open circuit, short circuit or poor contact.
5. Check the connections and wiring between the fuser (DP612S) and the drive PWB ( P/
J416) for an open circuit, short circuit or poor contact.
6. If the fault persists, install new components as necessary:
• Fuser, PL 10.05 Item 2.
• LVPS, PL 1.10 Item 8.
•Drive PWB, PL 1.10 Item 3.