April 2017
2-19
Xerox® VersaLink® B7025/B7030/B7035 Multifunction Printer
003-344, 003-345, 003-346
Status Indicator RAPs
Launch Issue
003-344 Hotline Fail RAP
003-344 Hotline failure during power on.
Procedure
WARNING
Ensure that the electricity to the machine is switched off while performing tasks that do
not need electricity. Refer to GP 10. Disconnect the power cord. Electricity can cause
death or injury. Moving parts can cause injury.
Perform the steps that follow:
1. Switch off, then switch on the machine, GP 10.
2. Ensure that all connectors on the drive PWB, PL 1.10 Item 3 and the ESS PWB, PL 3.10
Item 6 are securely connected. Ensure all surface mounted modules on both PWBs are
securely connected.
3. Reload the software, GP 4.
4. Perform the OF2 Special Boot Modes RAP.
003-345, 003-346 X PIO Mismatch RAP
003-345 When a job fail was received from the IISS, an error of the X hot line was detected.
003-345 When IIT image delivered was received from the IISS, an error of the X hot line was
detected.
Procedure
WARNING
Ensure that the electricity to the machine is switched off while performing tasks that do
not need electricity. Refer to GP 10. Disconnect the power cord. Electricity can cause
death or injury. Moving parts can cause injury.
Perform the steps that follow:
1. Switch off, then switch on the machine, GP 10.
2. Ensure that all connectors on the drive PWB, PL 1.10 Item 3 and the ESS PWB, PL 3.10
Item 6 are securely connected. Ensure all surface mounted modules on both PWBs are
securely connected.
3. Reload the software, GP 4.
4. Perform the OF2 Special Boot Modes RAP.