EasyManuals Logo
Home>Xerox>All in One Printer>VersaLink B7030

Xerox VersaLink B7030 Service Manual

Xerox VersaLink B7030
1341 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #633 background imageLoading...
Page #633 background image
April 2017
3-25
Xerox® VersaLink® B7025/B7030/B7035 Multifunction Printer
IQS 3, IQS 4
Imaqe Quality
Launch Issue
Figure 1 Test pattern
IQS 4 Resolution
Documents
Test patterns: 82E2000 (A3 and 11x17) 82E2010 (A4) 82E2020 (8.5x11).
Specification
Copy
Make 3 copies of a test pattern from the document glass. Examine the targets of the second
copy to determine the overall resolution of the copy. The lines identified by the letter H, Figure
1, should be clearly reproduced at 100%.
Print
Make 3 prints of internal test pattern 51 or 52. Examine the lines of the second print. All lines
should be resolved.
Corrective Action
If the resolution specification is not met, perform the IQ17 Smear RAP.
Figure 1 Test pattern
Rub these areas with a finger.
Fold the print across these solid areas