April 2017
2-510
Xerox® VersaLink® B7025/B7030/B7035 Multifunction Printer
116-348, 349, 358, 360, 374, 116-353, 354, 356, 361, 362
Launch Issue
Status Indicator RAPs
116-348, 349, 358, 360, 374 Redirecter Fail RAP
116-348 Various fatal errors detected in the redirecter.
116-349 An error occurred when calling the Pflite function using the SIF.
116-358 Fatal error related to salutation.
116-360 Fatal error related to SMB.
116-374 Fatal error of auto SW.
Procedure
WARNING
Ensure that the electricity to the machine is switched off while performing tasks that do
not need electricity. Refer to GP 10. Disconnect the power cord. Electricity can cause
death or injury. Moving parts can cause injury.
Perform the steps that follow:
1. Advise the customer to check that the TCP/IP ports are correctly configured.
2. Switch off, then switch on the machine, GP 10.
3. Ensure that all connectors on the drive PWB, PL 1.10 Item 3 and the ESS PWB, PL 3.10
Item 6 are securely connected. Ensure all surface mounted modules on both PWBs are
securely connected.
4. Reload the software, GP 4.
5. Perform the 016A Scan to Network Error Entry RAP.
6. Perform the OF2 Special Boot Modes RAP.
116-353, 354, 356, 361, 362 HDD Fail RAP
116-353 The HDD was not booted due to a physical HDD failure detected on booting.
116-354 The M/C was not started up due to a product code error detected in the HDD on boot-
ing.
116-356 The M/C was not started up due to an insufficient HDD capacity error detected during
HDD formatting.
116-361 Fatal error of SPL HDD.
116-362 SSDP Software Fail.
Procedure
Perform the 016-210, 506, 777, 780, 798 HDD Error RAP.