Trunk Property
Indicates the networking type of each trunk.
Value Range
Public, Private, VPN
Maintenance Console Location
9.11 PBX Configuration—[1-1] Configuration—Slot—V-IPGW—Shelf Property
Outgoing Call
First-digit Timer (T302-1)
Specifies the length of time within which the first digit of a dial number must be dialled after seizing a virtual IP
trunk.
Value Range
5–30 s
Maintenance Console Location
9.11 PBX Configuration—[1-1] Configuration—Slot—V-IPGW—Shelf Property
Inter-digit Timer (T302-2)
Specifies the length of time within which subsequent digits of a dial number must be dialled.
Value Range
1–10 s
Maintenance Console Location
9.11 PBX Configuration—[1-1] Configuration—Slot—V-IPGW—Shelf Property
Dial End Code
Specifies the delimiter code to be used to signal the end of a dialled number.
Value Range
0–9, #, *
Maintenance Console Location
9.11 PBX Configuration—[1-1] Configuration—Slot—V-IPGW—Shelf Property
Incoming Call
Voice Activity Detection for G.711
Enables the use of the Voice Activity Detection feature for the G.711 codec. This feature conserves bandwidth
by detecting silent periods during a call and suppressing the packets of silence from being sent to the network.
PC Programming Manual 285
9.11 PBX Configuration—[1-1] Configuration—Slot—V-IPGW—Shelf Property