Incoming Call Wait Timer for Extension Caller ID
Specifies the length of time that the ringing for a call is delayed when the call follows immediately after the
previous unanswered call. When receiving two calls in quick succession (e.g., when a call waiting in a queue
is directed to an extension immediately after the previous unanswered call stops ringing), some SLTs require
a pause, after the first call stops ringing, to receive the second call’s Caller ID information.
Value Range
0–15 s
Maintenance Console Location
12.1.1 PBX Configuration—[4-1-1] Extension—Wired Extension—Extension Settings
Feature Guide References
2.19.1 Caller ID
SLT MW Mode
Enables the use of the Message Waiting Lamp on an SLT extension connected to the extension port.
Value Range
Disable, MW-Lamp
Maintenance Console Location
12.1.1 PBX Configuration—[4-1-1] Extension—Wired Extension—Extension Settings
Feature Guide References
2.20.1 Message Waiting
Wrap-up Timer
Specifies the length of time that must pass after completing a call before an extension will accept another call
when logged in as a member of an Incoming Call Distribution Group.
This timer is used when "
Options—Wrap-up Timer based on" is set to "Extension" in 11.5.3 PBX
Configuration—[3-5-3] Group—Incoming Call Distribution Group—Miscellaneous.
Value Range
0–3000 s
Maintenance Console Location
12.1.1 PBX Configuration—[4-1-1] Extension—Wired Extension—Extension Settings
PC Programming Manual References
11.5.1.1 PBX Configuration—[3-5-1] Group—Incoming Call Distribution Group—Group Settings—Member
List—
Wrap-up Timer
11.5.3 PBX Configuration—[3-5-3] Group—Incoming Call Distribution Group—Miscellaneous—
Options—Wrap-up Timer based on
PC Programming Manual 653