EasyManuals Logo

Panasonic KX-NS500 Pc Programming Manual

Panasonic KX-NS500
1064 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #429 background imageLoading...
Page #429 background image
10.1.2 PBX Configuration—[2-1-2] System—Date & Time—SNTP /
Daylight Saving
Automatic clock adjustment and Summer time (daylight saving time) settings of the PBX can be programmed.
Automatic clock adjustment can be performed using one of two methods, ISDN & Caller ID or SNTP (Simple
Network Time Protocol).
To set Summer time, click 10.1.2.1 PBX Configuration—[2-1-2] System—Date & Time—SNTP / Daylight
Saving—Daylight Saving.
Note
The NTP server function of the PBX must be enabled for connected KX-UT series SIP phones to receive
automatic time adjustment information from the PBX. See 27.2.4 Network Service—[2-5] Server
Feature—NTP.
Automatic Time Adjustment
Enables the PBX to automatically adjust its clock every day according to the time information provided by the
network.
Value Range
Disable, ISDN & Caller ID (FSK), SNTP
Maintenance Console Location
10.1.2 PBX Configuration—[2-1-2] System—Date & Time—SNTP / Daylight Saving
Feature Guide References
5.5.5 Automatic Setup
SNTP—SNTP Server—IP Address
Specifies the IP address or host name of the SNTP server.
Value Range
1.0.0.0–223.255.255.255 (IP address), Max. 253 characters (host name)
Maintenance Console Location
10.1.2 PBX Configuration—[2-1-2] System—Date & Time—SNTP / Daylight Saving
Feature Guide References
5.5.5 Automatic Setup
SNTP—SNTP Server—Port Number
Indicates the port number used for communication with an SNTP server (reference only).
Value Range
1–65535
PC Programming Manual 429
10.1.2 PBX Configuration—[2-1-2] System—Date & Time—SNTP / Daylight Saving

Table of Contents

Other manuals for Panasonic KX-NS500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Panasonic KX-NS500 and is the answer not in the manual?

Panasonic KX-NS500 Specifications

General IconGeneral
Analog ExtensionsUp to 64
VoIP SupportYes
System TypeHybrid IP-PBX
Power SupplyAC 100-240V, 50/60Hz
Operating Temperature0°C to 40°C
Humidity10% to 90% (non-condensing)
Maximum Extensions288
IP Extensions128
VoIP Channels64
SIP Trunks64
NetworkingYes, supports networking
Built-in ApplicationsCall Center
ExpandabilityYes, via expansion cards and cabinets
Supported ProtocolsSIP, H.323, MGCP
Dimensions430 x 88 x 367 mm