11.1.4 PBX Configuration—[3-1-4] Group—Trunk Group—Dialling
Plan
The PBX sends all of the dialled digits at once after an extension user completes dialling. The PBX can
recognise the end of dialling when the dialled telephone number starts with the programmed leading number
and contains the programmed total number of digits.
When the PBX recognises the end of dialling to an analogue trunk, the PBX cancels the muting of the caller’s
voice sent to the analogue trunk immediately. If the PBX cannot recognise the end of dialling, the PBX mutes
the caller’s voice sent to an analogue trunk from the time at which the last digit is dialled until the analogue
trunk inter-digit timer expires.
4 tables can be programmed, each with a maximum of 50 leading numbers. Select the table to programme
from the Dialling Plan Table list.
To assign a set of leading numbers automatically, click Auto Assign.
Leading Number
Specifies the leading number to be regarded as the beginning of dialling.
Value Range
Max. 32 digits (consisting of 0–9, *, #, N [2,3,4,5,6,7,8,9], P [0, 1], and X [0–9, *, and #])
Maintenance Console Location
11.1.4 PBX Configuration—[3-1-4] Group—Trunk Group—Dialling Plan
PC Programming Manual References
10.3 PBX Configuration[2-3] System—Timers & Counters—Dial / IRNA / Recall / Tone
Dial—Analogue
CO First Digit (s)
10.3 PBX Configuration[2-3] System—Timers & Counters—Dial / IRNA / Recall / Tone Dial—Analogue
CO Inter-digit (s)
11.1.1 PBX Configuration—[3-1-1] Group—Trunk Group—TRG Settings—Main— Dialling Plan Table
Feature Guide References
4.1.2.1 Integrated Services Digital Network (ISDN)—SUMMARY
Removed Number of Digits
Specifies the number of leading digits to be removed from the number dialled by en-bloc dialling.
Value Range
0–15
Maintenance Console Location
11.1.4 PBX Configuration—[3-1-4] Group—Trunk Group—Dialling Plan
Feature Guide References
4.1.2.1 Integrated Services Digital Network (ISDN)—SUMMARY
568 PC Programming Manual
11.1.4 PBX Configuration—[3-1-4] Group—Trunk Group—Dialling Plan

Table of Contents

Other manuals for Panasonic KX-NS500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Panasonic KX-NS500 and is the answer not in the manual?

Panasonic KX-NS500 Specifications

General IconGeneral
Analog ExtensionsUp to 64
VoIP SupportYes
System TypeHybrid IP-PBX
Power SupplyAC 100-240V, 50/60Hz
Operating Temperature0°C to 40°C
Humidity10% to 90% (non-condensing)
Maximum Extensions288
IP Extensions128
VoIP Channels64
SIP Trunks64
NetworkingYes, supports networking
Built-in ApplicationsCall Center
ExpandabilityYes, via expansion cards and cabinets
Supported ProtocolsSIP, H.323, MGCP