20.1.2 UM Configuration—[1-2] Mailbox Settings—Full Setting
Mailbox Parameters
Mailbox Number
Specifies the subscriber’s mailbox number. The maximum number of digits that can be used for mailbox
numbers is set in 24.4 UM Configuration—[5-4] System ParametersParametersMailbox Mailbox
No. Max. Length (3-8), or when you initialise the system.
Note
The mailbox number can only be set when adding a mailbox; when editing a mailbox, you cannot change
the assigned mailbox number.
Value Range
2–[the value set in
Mailbox No. Max. Length (3-8)] digits
Maintenance Console Location
20.1.2 UM Configuration—[1-2] Mailbox Settings—Full Setting—Mailbox Parameters
PC Programming Manual References
10.9 PBX Configuration—[2-9] System—System Options—Option 9
Feature Guide References
3.1.1 Unified Messaging System Overview
3.2.2 Subscriber Features—3.2.2.17 Mailbox
Extension
Specifies the extension number of the mailbox’s subscriber. Any valid extension number including an Extension
Group number can be assigned.
Note
If an Extension Group number is assigned to a mailbox, all group members are able to access the
messages stored in the mailbox.
Value Range
2–8 digits
Maintenance Console Location
20.1.2 UM Configuration—[1-2] Mailbox Settings—Full Setting—Mailbox Parameters
PC Programming Manual References
10.9 PBX Configuration—[2-9] System—System Options—Option 9
Feature Guide References
3.1.1 Unified Messaging System Overview
PC Programming Manual 855
20.1.2 UM Configuration—[1-2] Mailbox Settings—Full Setting

Table of Contents

Other manuals for Panasonic KX-NS500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Panasonic KX-NS500 and is the answer not in the manual?

Panasonic KX-NS500 Specifications

General IconGeneral
Analog ExtensionsUp to 64
VoIP SupportYes
System TypeHybrid IP-PBX
Power SupplyAC 100-240V, 50/60Hz
Operating Temperature0°C to 40°C
Humidity10% to 90% (non-condensing)
Maximum Extensions288
IP Extensions128
VoIP Channels64
SIP Trunks64
NetworkingYes, supports networking
Built-in ApplicationsCall Center
ExpandabilityYes, via expansion cards and cabinets
Supported ProtocolsSIP, H.323, MGCP
Dimensions430 x 88 x 367 mm