6.4.3 Thrust bearing - do a check of the axial clearance with a inside
micrometer
Periodicity
Description
Working hours 7000
Duration for performing preliminary requirements 0.0 man-hours
Duration for performing the procedure 0.5 man-hours
Duration for performing the requirements after job completion 0.0 man-hours
Personnel
Description Specialization QTY
Engine crew Basic AR
Support equipment
Description Part No. CSN QTY
Micrometer 94101 1
Supplies
Description QTY
None
Spare Parts
Description Part No. CSN QTY
None
SAFETY PRECAUTIONS
None
PRELIMINARY OPERATIONS
The engine must be stopped and made safe for maintenance, refer to section 4.1 Do
maintenance work - general procedure
X72DF
AA00-1203-00AAA-360B-A
Maintenance Manual Thrust bearing - do a check of the axial clearance with a inside
micrometer
Winterthur Gas & Diesel Ltd.
- 136 - Issue 002 2020-10