9.2 Shut-off valve for starting air
9.2.1 Shut-off valve for starting air - disassemble
Periodicity
Description
Working hours 33 000
Duration for performing preliminary requirements 0.0 man-hours
Duration for performing the procedure 1.0 man-hours
Duration for performing the requirements after job completion 0.0 man-hours
Support equipment
Description Part No. CSN QTY
None
Supplies
Description QTY
None
Spare Parts
Description Part No. CSN QTY
None
SAFETY PRECAUTIONS
• None
PRELIMINARY OPERATIONS
• The engine must be stopped and made safe for maintenance, refer to section 4.1 Do
maintenance work - general procedure
X72DF
AA00-4325-00AAA-530A-A
Maintenance Manual Shut-off valve for starting air - disassemble
Winterthur Gas & Diesel Ltd.
- 516 - Issue 002 2020-10