7.3.2 Gas admission valve - remove
Periodicity
Description
Working hours 19 500
Duration for performing preliminary requirements 0.0 man-hours
Duration for performing the procedure 1.0 man-hours
Duration for performing the requirements after job completion 0.0 man-hours
Personnel
Description Specialization QTY
Engine crew Basic AR
Support equipment
Description Part No. CSN QTY
Disassembly / assembly
tool
N/A 1
Eye bolt 94218 1
Supplies
Description QTY
Molykote G-Rapid Plus A/R
Spare Parts
Description Part No. CSN QTY
None
SAFETY PRECAUTIONS
WARNING
Danger - If a gas detector alarm is activated, keep away from the engine. The natural gas
is flammable. There is a risk of fire or explosion.
WARNING
Injury Hazard - When you open valves and shut-off devices, hot fluids or gases can be
released. To prevent injury, always open slowly the valves and shut-off devices. Look
away from where the gas is released.
NOTE: For safety, it is recommended that you have a portable gas detector.
PRELIMINARY OPERATIONS
• The engine must be stopped and made safe for maintenance, refer to section 4.1 Do
maintenance work - general procedure
X72DF
AA00-2140-00AAA-520A-A
Maintenance Manual Gas admission valve - remove
Winterthur Gas & Diesel Ltd.
- 206 - Issue 002 2020-10