7.3.4 Gas admission valve - disassemble
Periodicity
Description
Working hours 19 500
Duration for performing preliminary requirements 0.0 man-hours
Duration for performing the procedure 1.0 man-hours
Duration for performing the requirements after job completion 0.0 man-hours
Personnel
Description Specialization QTY
Engine crew Basic AR
Support equipment
Description Part No. CSN QTY
Disassembly / assembly
tool
94214 1
Pusher 94214D 1
Bush 94214E 1
Supplies
Description QTY
Molykote G Rapid Plus A/R
Spare Parts
Description Part No. CSN QTY
None
SAFETY PRECAUTIONS
None
PRELIMINARY OPERATIONS
The GAV must be removed, refer to section 7.3.2 Gas admission valve - remove