7.8.2 Relief valve combustion chamber - install
Periodicity
Description
Unscheduled
Duration for performing preliminary requirements 0.0 man-hours
Duration for performing the procedure 1.0 man-hours
Duration for performing the requirements after job completion 0.0 man-hours
Personnel
Description Specialization QTY
Engine crew Basic AR
Support equipment
Description Part No. CSN QTY
None
Supplies
Description QTY
Never Seez NSBT A/R
Spare Parts
Description Part No. CSN QTY
Relief valve combustion
chamber
1
Sensor complete 1
O-ring 2
SAFETY PRECAUTIONS
None
PRELIMINARY OPERATIONS
The relief valve must be removed, refer to section 7.8.1 Relief valve combustion chamber
- remove
X72DF
AA00-2740-00AAA-720A-A
Maintenance Manual Relief valve combustion chamber - install
Winterthur Gas & Diesel Ltd.
- 290 - Issue 002 2020-10