10/00
4-39
Phaser 790/DocuColor 2006
REP 6.5, REP 6.6
Repairs and Adjustments
Initial Issue
REP 6.5 Angle Sensor
Parts List on PL 16.1
Removal
WARNING
To avoid personal injury or shock, do not perform repair activities with the power switch
on or electrical power applied to the machine.
1. Switch off the machine power and disconnect the machine Power Cord.
2. Remove the Rear Cover (REP 6.4)
3. Remove the Angle Sensor (Figure 1).
Figure 1 Removing the Angle Sensor
Replacement
1. Perform the procedure for removal in reverse.
REP 6.6 Platen Switch
Parts List on PL 16.1
Removal
WARNING
To avoid personal injury or shock, do not perform repair activities with the power switch
on or electrical power applied to the machine.
1. Switch off the machine power and disconnect the machine Power Cord.
2. Remove the Platen Glass (REP 6.1).
3. Remove the Control Panel Assembly (REP 6.23)
4. Remove the Platen Switch (Figure 1).
Figure 1 Removing the Platen Switch
Replacement
1. Perform the procedure for removal in reverse.
1
Disconnect
the connector
2
Remove the screw and the
Angle Sensor
1
Disconnect the connector
and release the wires from
the clip
2
Remove the screw and
the Platen Switch