10/00
4-50
Phaser 790/DocuColor 2006
REP 6.19, REP 6.20
Initial Issue
Repairs and Adjustments
REP 6.19 Belt
Parts List on PL 16.4
Removal
WARNING
To avoid personal injury or shock, do not perform repair activities with the power switch
on or electrical power applied to the machine.
1. Switch off the machine power and disconnect the machine Power Cord.
2. Remove the Carriage Motor (REP 6.18).
3. Remove the Belt (Figure 1).
Figure 1 Removing the Belt
Replacement
1. Perform the procedure for removal in reverse.
REP 6.20 Lamp
Parts List on PL 16.5
Removal
WARNING
To avoid personal injury or shock, do not perform repair activities with the power switch
on or electrical power applied to the machine.
1. Switch off the machine power and disconnect the machine Power Cord.
2. Remove the Platen Glass (REP 6.1).
3. Move the Full-rate Carriage so that it is aligned with the notches in the center of the scan-
ner frame.
4. Remove the Lamp (Figure 1).
Figure 1 Removing the Lamp
Replacement
1. Perform the procedure for removal in reverse.
1
Remove the Belt
1
Disconnect the
connector
2
Remove the screw and then remove the
Lamp by turning it in the direction indicated
Scanner
frame
Notches