Phaser 790/DocuColor 2006
003-334
Status Indicator RAPs
Initial Issue
003-334 Foreign Interface Compatibility RAP
This Fault Code indicates that a compatibility problem was detected between the ESS PWB
and the Foreign Interface (an incorrect Foreign Interface device may be installed).
Procedure
Switch the IOT power off, then on. Fault Code 003-334 is still present.
YN
If intermittent performance is suspected, perform the following:
• Check the connections between the ESS PWB and the Foreign Interface and the
interconnecting harness.
• Reseat the P/J 17 connector on the ESS PWB and P/J 905 on the Foreign Interface.
The Foreign Interface device is the correct device for the P790/DC2006.
YN
Install the correct Foreign Interface.
Go to Flag 1 and check the wires for an open or short circuit. The wires are good.
YN
Repair the wires.
Replace the Foreign Interface.