27 - 38
27.2 MELSECNET/10 Connection (PLC To PLC Network)
27.2.10 CNC Side Settings
27.2.10 CNC Side Settings
1 Parameter Setting
Set parameters related to MELSECNET/10 with MELSEC’s peripheral devices in the same way as
parameter setting of MELSEC CPU, and write them on CNC by PC. However, in the case of using the
default parameters or not requiring separate settings due to normal stations, it is not necessary to set
the network
(1) Control Station Parameter
If you wish to place the control station in CNC and set the common parameters, set the network
parameters by peripheral device and write them on CNC. An example of parameter setting by
GPPW is as follows.
Set the first I/O No. as follows according to the expansion slot to which the unit is inserted.
(a) Start I/O No.
(b) Example of GX Developer setting
For details of the parameter setting, refer to the following.
MELDAS C6/C64 NETWORK MANUAL BNP-B2373
(2) Normal Station Parameter
As for normal stations, it is not necessary to set parameters unless separate settings are required.
The refresh parameters are set and written as required. In this case, the parameter setting of the
first I/O No. is the same as in the case of the control station.
Slot Start I/O No.
EXT1 0200
EXT2 0280
EXT1
EXT2