EasyManuals Logo
Home>Siemens>Servo Drives>SINAMICS SIMOTICS S200 PROFINET

Siemens SINAMICS SIMOTICS S200 PROFINET User Manual

Siemens SINAMICS SIMOTICS S200 PROFINET
908 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #104 background imageLoading...
Page #104 background image
5.1.4 Minimum clearances
Description
Obser
ve the following minimum mounting clearances. For converters without built-in fans,
install cooling fans above the converters for su󹪟cient heat dissipation.
Note
F
or con
verters without built-in fans, when the surrounding temperature in the cabinet is 45 °C,
the air󹪞ow velocity above the converters must be greater than 0.5m/s.
All dimensions are speci󹪝ed in millimeter
s.

$
$
Table 5-3 Minimum clearances to other devices or components
Single-converter instal‐
lation
Side-by-side installation
Minimum clearance at top and
bottom
100mm 100mm
Minimum clear
ance at front 85mm 85mm
Minimum lateral clearance (A)
be
tween multiple con
verters
- 200V converter: 1mm
400V converter: 10mm
A mixture of 200 V and 400 V converters:
10mm
Minimum lateral clearance to
other de
vices
10mm 10mm
Mounting
5.1Converter
SINAMICS S200 PROFINET servo drive system with SIMOTICS S-1FL2
102 Operating Instructions, 11/2023, FW V6.3, A5E51646752B AB

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINAMICS SIMOTICS S200 PROFINET and is the answer not in the manual?

Siemens SINAMICS SIMOTICS S200 PROFINET Specifications

General IconGeneral
BrandSiemens
ModelSINAMICS SIMOTICS S200 PROFINET
CategoryServo Drives
LanguageEnglish

Related product manuals