7.3.4 Security settings
Overvie
w
The Security Wizard oers the following settings:
• User Management & Access Control (UMAC)
• Access to the integrated web server via the eldbus or service interface
• Drive data encryption
Requirement
NOTICE
Data manipulation due to low protection
An inadequat
ely protected drive makes it easier for potential attackers to access the drive data.
Data manipulation can cause the drive to malfunction or damage it.
You can nd information about the following actions on the Internet:Industrial Cybersecurity
Conguration Manual (
https://support.industry.siemens.com/cs/ww/en/view/109810578).
• Only use
the low security settings in exceptional cases and only if an information security
risk analysis nds that it is reasonable to do so.
• Congure the settings for full protection immediately after adding a drive or several drives
to the project.
Description of function
One of the follo
wing options can be selected:
• "Congure security settings"
Siemens recommends this setting for comprehensive protection.
• "Continue with low security settings"
With this setting, UMAC is deactivated.
You can congure the settings at a later time. You can nd the settings in Section "Protection
& Security (Page211)".
Commissioning (web server)
7.3Getting started
SINAMICS S200 PROFINET servo drive system with SIMOTICS S-1FL2
174 Operating Instructions, 11/2023, FW V6.3, A5E51646752B AB