– Enter the drive password congured in st
ep 2.
The drive password congured in this step corresponds to the drive password with which
the drive data in the backup le were encrypted.
A dialog to enter the password opens.
– Enter the drive password that was used to encrypt the drive data in the backup le.
The drive data are loaded into the converter from the backup le.
As a consequence, the status of the settings at the instant of the backup are restored.
Function "Drive data encryption" is activated. The originally congured drive password is
applied.
7.4.6.6 Restore factory settings
Overview
The reset to factory settings with the web server deletes the user-specic parameterization of the
converter, for example the motor data.
The following data are retained when the factory settings are restored:
• Communication interface settings
• Security settings (including UMAC)
• Language setting
• Date and time
In the following cases it may be necessary to restore the converter to factory settings:
• If the motor is changed
• If there is uncertainty regarding the previous parameterization and/or the previous use of the
converter
Requirement
If User Management & Access Control is activated, you will need the following function rights:
• Edit device conguration or drive applications
Procedure
1. Call the "Backup and restore" menu.
2. Click the "Restore factory settings" button.
3. Acknowledge the conrmation prompt.
The converter is reset and then restarted.
More information
For a full reset of the converter, proceed as described in Chapter "Reset of all user-dened
settings to the factory setting via an SD card (Page587)".
Commissioning (web server)
7.4Functions and menus
SINAMICS S200 PROFINET servo drive system with SIMOTICS S-1FL2