More information
To comply with product standards of plants and/or machines, when integrating the converter in
plants or machines, additional measures may be required. The additional measures are the
responsibility of the plant builder or machine OEM.
Disturbance-free operation of the converter is only guaranteed when specialist personnel
carry out the installation work in strict compliance with EMC regulations.
4.7.5 EMC limit values in South Korea
Description
The EMC limit values to be observed for Korea correspond to the limit values of the EMC
product st
andard for variable-speed electric drives EN61800-3 of categoryC2 or the limit
value classA, Group1 to KN11.
By implementing appropriate additional measures, the limit values according to categoryC2
or limit value classA, Group1, are observed.
Additional measures, such as the use of an additional RFI suppression lter (EMC lter), may
be necessary.
In addition, measures for EMC-compliant conguration of the plant or system are described
in detail in this manual.
The nal statement on compliance with the applicable standard is given by the respective
label attached to the individual device.
4.7.6 Harmonic current emissions
Overview
IEC61800‑3 does not dene any current harmonic limits when converters are operated on
industrial line supplies. A system evaluation according to IEC61800‑3AnnexB.4 is
recommended.
Application planning
4.7Electromagnetic compatibility (EMC)
SINAMICS S200 PROFINET servo drive system with SIMOTICS S-1FL2
90 Operating Instructions, 11/2023, FW V6.3, A5E51646752B AB