Certicates of License (eCoL)
Under "Cer
ticates of License (eCoL)", you load purchased licenses directly from an SD card
into the le system of the operating unit.
7.4.7.5 Firmware update
Overview
You can perform a rmware update in the web server:
• For an upgrade, the converter and web server settings are retained.
• For a downgrade, the converter and web server are reset to factory settings. All user-dened
settings are reset to the factory settings, including:
– Parameterization of the converter
– Activation and settings of User Management & Access Control
– "IP conguration" and "Device name" communication settings of the service interface
(X127)
– Self-generated certicates
– User-dened parameter lists in the web server
Requirement
• The operating unit is connected to the converter's web server.
• An empty SD card is inserted into the card slot of the converter before starting the rmware
update for storing the user data temporarily.
Note: The SD card must be inserted when the converter is switched o.
• The converter is in servo-o state.
Description of function
This function view "Firmware update" displays the current version of the rmware and of the web
server.
To copy a dierent rmware version to the converter, load the ZIP le containing the rmware
from the le system of the operating panel.
7.4.7.6 About web server
Overview
"About web server" contains information about the web server and links to additional
information.
Commissioning (web server)
7.4Functions and menus
SINAMICS S200 PROFINET servo drive system with SIMOTICS S-1FL2
Operating Instructions, 11/2023, FW V6.3, A5E51646752B AB 215