Requirement
• For activated user management (UMAC):
The function rights for editing drive data are activated for your user account.
Details on this topic are provided in Chapter "Security settings in Startdrive" of Industrial
Cybersecurity Conguration Manual (https://support.industry.siemens.com/cs/ww/en/view/
109810578).
Procedure
Pr
oceed in either of the following ways to save changes in the project:
• In the toolbar, click the
icon.
• Select the "Pr
oject > Save" or "Project > Save as" menu.
8.3.7 Retentively saving changes to the SD card
Overview
Parameter assignments of your converter are always volatile and are lost when the converter is
switched o. Information is subsequently provided as to how you can retentively save online
data or oine data.
Requirement
• A project has been created.
• A drive has been created and completely congured in the project.
• For activated user management (UMAC):
The function rights for editing drive data are activated for your user account.
Details on this topic are provided in Chapter "Security settings in Startdrive" of Industrial
Cybersecurity Conguration Manual (
https://support.industry.siemens.com/cs/ww/en/view/
109810578).
Procedure
R
etentively saving online data
Proceed in either of the following ways to save online data retentively:
• In the function view of the active Startdrive project, click the
icon.
• In the pr
oject tree of your drive device, double-click "Online & Diagnostics".
– In the secondary navigation select the "Functions > Backup/Restore" menu.
– In the "Retentively save RAM data" area, click "Save".
The system checks whether an SD card is available. If an appropriate SD card is detected, then
the parameter values are retentively saved to the SD card.
Commissioning (Startdrive)
8.3Basics
SINAMICS S200 PROFINET servo drive system with SIMOTICS S-1FL2
Operating Instructions, 11/2023, FW V6.3, A5E51646752B AB 227