Group Settings
Time synchronization/Time
Option "Synchronize with NTP server"
If
the
drive is connected to a controller in the device con󹪝guration, the option "Use PLC as
NTP server" is activated automatically.
If the drive is connected to a PLC, the IP address of the PLC is displayed. In this case, the IP
address and the time zone of the NTP server can be changed.
Option "No synchronization"
In this case, NTP synchronization is not managed in the project. You can con󹪝gure this
synchronization separately for the drive in online mode with the Online & Diagnostics
function "Set time".
Hardware settings
Supply voltage
Web server
Enabling
access
to the PROFINET interface [X150] and the service interface [X127] via HTTP
or HTTPS.
Requirement
A new pr
oject has been created or an existing project is open.
An S200 drive has been created in the project.
For activated user management (UMAC):
The function rights for editing drive data are activated for your user account.
Details on this topic are provided in Chapter "Security settings in Startdrive" of Industrial
Cybersecurity Con󹪝guration Manual (
https://support.industry.siemens.com/cs/ww/en/view/
109810578).
Procedure
1
. Select the converter in the device view and open the inspector window.
2. In the secondary navigation of the inspector window, select the desired detail menu (see the
table above).
3. Make the required detail settings in the white 󹪝elds. Default settings are usually available in
most detail menus.
The gray 󹪝elds are corrected automatically in accordance with their setting. Fields with a gray
background cannot be edited directly.
Result
You have made the detailed settings for the converter in your device con󹪝guration.
8.5.1.4 Specifying a motor
Overview
The drive that has just been inserted in the project has a placeholder for the required motor
(standard motor type: "1FL2"). You must specify this placeholder in the con󹪝guration.
Commissioning (Startdrive)
8.5Combining and con󹪝guring devices in the pr
oject
SINAMICS S200 PROFINET servo drive system with SIMOTICS S-1FL2
Operating Instructions, 11/2023, FW V6.3, A5E51646752B AB 241

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINAMICS SIMOTICS S200 PROFINET and is the answer not in the manual?

Siemens SINAMICS SIMOTICS S200 PROFINET Specifications

General IconGeneral
BrandSiemens
ModelSINAMICS SIMOTICS S200 PROFINET
CategoryServo Drives
LanguageEnglish

Related product manuals