3.4.3.1 Recommended line lters
Table 3-9 Recommended line lters
Converter frame size Rated current (A) Article number Degree of protection
1 AC, 200V ... 240V
FSA/FSB/FSC 18 6SL5550-0XB21-8CA0 IP20
3 AC, 200V ... 240V
FSA/FSB/FSC 5 6SL3203-0BE15-0VA0 IP20
3 AC, 380V ... 480V
FSA/FSB 5 6SL5550-0XE20-5CA0 IP20
FSC 12 6SL5550-0XE21-2CA0
FSD 20 6SL5550-0XE22-0CA0
3.4.3.2 Technical data
Technical dat
a
Table 3-10 Technical data of line lters
Article number 6SL5550-0XB21
-8C
A0
6SL3203-0BE15
-0VA0
6SL5550-0XE20
-5CA0
6SL5550-0XE21
-2CA0
6SL5550-0XE22
-0CA0
Line volt
age (V) 200 ... 240 V,
1 AC
275 ... 480 V,
3 A
C
275 ... 480 V,
3 AC
275 ... 480 V,
3 AC
275 ... 480 V,
3 AC
Rated current (A) 18 5 5 12 20
Power loss (W) 4.7 2 2.7 3.9 10.1
Type of connection Screw terminals Screw terminals Screw terminals Screw terminals Screw terminals
Conductor cross-section (mm
2
)
For single-conductor
connection
0.75 ... 6
(A
WG 18 ... 10)
0.75 ... 6
(A
WG 18 ... 10)
0.75 ... 6
(AWG 18 ... 10)
0.75 ... 6
(AWG 18 ... 10)
0.75 ... 6
(AWG 18 ... 10)
For exible cable
connection
0.75 ... 4
(AWG 18 ... 10)
0.75 ... 4
(A
WG 18 ... 10)
0.75 ... 4
(AWG 18 ... 10)
0.75 ... 4
(AWG 18 ... 10)
0.75 ... 4
(AWG 18 ... 10)
Insulation stripping length
(mm)
8 ... 9 8 ... 9 8 ... 9 8 ... 9 8 ... 9
Protective conductor
connection
M5 M6 M6 M6 M6
Degree of protection IP20 IP20 IP20 IP20 IP20
Dimensions (W × H × D, mm) 58 × 155 × 53 55 × 170 × 130 55 × 170 × 130 75 × 195 × 140 60 × 250 × 130
Weight (kg) 0.75 0.67 0.72 1.34 1.5
Leakage current (mA) 11.84 4.31 4.37 7.05 8.88
Description
3.4Accessories
SINAMICS S200 PROFINET servo drive system with SIMOTICS S-1FL2
64 Operating Instructions, 11/2023, FW V6.3, A5E51646752B AB