Acknowledgment
A fault can only be ackno
wledged if the cause has been resolved.
The acknowledgment species when the fault can be acknowledged.
An alarm is self-acknowledging.
Table 12-7 Acknowledging faults
Acknowledg‐
ment
Description
IMMEDIATELY Acknowledgment can be immediately realized after the cause has been resolved.
PULSE INHIBIT Once the cause has been resolved, the fault can only be acknowledged when the
pulses are inhibited (r0899.11 = 0).
PO
WER ON The fault can only be acknowledged using POWER ON (the converter is switched-o/
switched-on).
NONE F
or alarms (type "A"), an acknowledgment is not required.
Cause
Describes the pos
sible causes of the fault or alarm. Optionally, a message value, fault value
or alarm value can be additionally specied.
Remedy
Generally explains possible procedures to resolve the cause of this active fault or alarm.
12.3.5 List of fault codes and alarm codes
Product: SINAMICS S200, Version: 603021000, Language: eng
Objects: S200 Basic PN, S200 PN
F01000 Internal software error
Message class: Hardware/software error (1)
Message value: Module: %1, line: %2
Component: Control Unit (CU)
Response: OFF2
Acknowledgment: POWER ON
Cause: An internal software error has occurred.
F
ault value (r0949, int
erpret hexadecimal):
Only for internal Siemens troubleshooting.
Remedy: - Evaluate fault buer (r0945).
- Carry out a POWER ON (switc
h-o/switch-on) for all components.
- If required, check the data on the non-volatile memory (e.g. memory card).
- Upgrade rmware to later version.
- Contact Technical Support.
- Replace the converter.
F01001 FloatingPoint exception
Message class: Hardware/software error (1)
Message value: %1
System messages
12.3Faults and alarms
SINAMICS S200 PROFINET servo drive system with SIMOTICS S-1FL2
436 Operating Instructions, 11/2023, FW V6.3, A5E51646752B AB