Requirement
• The connection between the converter and control system is disconnected.
• For activated user management (UMAC):
The function rights required to edit drive data are activated for your user account.
Details on this topic are provided in Chapter "Security settings in Startdrive" of Industrial
Cybersecurity Conguration Manual (https://support.industry.siemens.com/cs/ww/en/view/
109810578).
Procedure
Pr
oceed as follows to reset the parameter assignment of the PROFINET interfaces to the factory
settings:
1. Expand the "Functions" entry in the secondary navigation.
2. Click the "Reset of PROFINET interface parameters" entry.
The corresponding screen form opens.
3. Select one of the following options:
– Retain I&M data
If the option "Retain I&M data" is active, the I&M1 to I&M3 data are retained.
– Delete I&M data
If the option "Delete I&M data" is active, the I&M1 to I&M3 data are deleted.
4. Click the "Reset" button.
Result
The parameters of the PROFINET interfaces are reset. The reset data are displayed in the "Online
access" function view.
More information
More information on restoring the factory settings is provided in Chapter "Restore factory
settings (Page306)".
8.9.6.2 Setting the time-of-day
Overview
The option "Synchronize with an NTP server" is activated when the "Set time" diagnostics view
is called up for the rst time.
Commissioning (Startdrive)
8.9Using online diagnostic functions
SINAMICS S200 PROFINET servo drive system with SIMOTICS S-1FL2
302 Operating Instructions, 11/2023, FW V6.3, A5E51646752B AB