13.3 Service and maintenance for spare parts
13.3.1 Spare par
ts and spare parts compatibility
Overview
Spare parts can be ordered on the Internet via the spare parts service Spares on Web (
https://
www.sow.siemens.com/).
Spares on Web also giv
es you the option of determining the article numbers of spare parts.
Description
Converter components are being continuously developed within the scope of product
maintenance.
Product maintenance includes, for example, measures to increase the ruggedness or
hardware changes that become necessary as components are discontinued.
These further developments are "spare parts-compatible" and do not change the article
number.
In the scope of such spare parts-compatible ongoing development, connectors or connection
positions are sometimes slightly modi󹪝ed. This does not cause any problems when the
component is used as intended. Take this fact into consideration in special installation
situations (for example, allow su󹪟cient reserve regarding the cable length).
13.3.2 Replacing the fan unit (400 V converters FSC and FSD only)
Overview
The 400 V converters FSC and FSD are integrated with a fan unit.
The service life of the fan can reach 20000 hours at the rated operating temperature and the
average 100% operating load; however, the service life may be shorter, especially in a dusty
environment.
Parameter r0277 is used to display the fan wear as a percentage of the operating hours.
Alarm A30042 appears if the maximum operating hours will soon be reached or has already
been exceeded.
The alarm value is contained in r2124 (interpret as a binary value):
Bit 0 = 1: The wear counter has reached 99%, and after the remaining 1% has elapsed, bit 0
is cleared and bit 2 is set.
Bit 2 = 1: The wear counter has exceeded 100%.
Replace the defective fan in time to ensure the proper operation of the converter.
Corrective maintenance
13.3Service and maintenance for spare parts
SINAMICS S200 PROFINET servo drive system with SIMOTICS S-1FL2
Operating Instructions, 11/2023, FW V6.3, A5E51646752B AB 605

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINAMICS SIMOTICS S200 PROFINET and is the answer not in the manual?

Siemens SINAMICS SIMOTICS S200 PROFINET Specifications

General IconGeneral
BrandSiemens
ModelSINAMICS SIMOTICS S200 PROFINET
CategoryServo Drives
LanguageEnglish

Related product manuals