HYDRAULIC COOLING FAN SYSTEM
BLEEDING
EG0AA–01
1. CHECK FLUID LEVEL IN RESERVOIR TANK
If low, add fluid.
Fluid:
ATF DEXRON II
HINT: Check that fluid level is within the ”HOT” level on reser-
voir tank. If the fluid is cold, check that it is within the ”COLD”
level on the tank.
2. BLEED COOLING SYSTEM
(a) Using SST, connect terminals OP1 and E1 of the data link
connector 1.
SST 09843–18020
(b) Start the engine without depressing the accelerator pedal.
(c) Leave the engine running for several seconds.
(d) Check that there is no foaming and emulsification of the fluid
in the reservoir tank.
–ENGINE TROUBLESHOOTING COOLING SYSTEM
EG–265