SECTION 6
6-19
MODEL TX67 -- DRIVING THE COMBINE AFTER MANUAL RESET
If not possible to select gears or to release the hand-
brake, it is not possible to drive the combine as there
is no power supply to the hydrostatic drive printed cir-
cuit. It is, however, possible to select gears and to re-
lease the handbrake manually (see above). To pro-
vide power to the hydrostatic drive printed circuit,
plug connector X into connector Y.
9
55386