CHAPTER 7 FIXING SYSTEM
COPYRIGHT
©
2002 CANON INC. 2000 CANON iR1600/iR2000 REV.1 JAN. 2002
7-7
2.2.4 Control in ESS (energy save mode)
In ESS mode, the machine may be in one of two states, depending on the selection of
‘power at time of energy save mode’ (‘high’ or ‘low <default>’); hereafter, the former is
referred to as ESS1 and the latter, ESS2.
Control for ESS1:
When the machine is in ESS1 state, the control temperature of the fixing heater is lowered
to 120ºC from 140ºC (standby temperature).
The target temperature at the end of ESS1 is determined in relation to the fixing tempera-
ture and the printer state, as in the case of temperature control used at power-on.
Control for ESS2:
When the machine is in ESS2 state, the fixing heater (H101) remains OFF.
The target temperrature at the end of ESS2 is determined in relation to the fixing tempera-
ture and the printer state, as in the case of temperature control at power-on.
Memo
The power save mode (energy save mode) for user mode at time of ship-
ment from the factory is set to 15 min.

Table of Contents

Other manuals for Canon IR1600

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Canon IR1600 and is the answer not in the manual?

Canon IR1600 Specifications

General IconGeneral
Print TechnologyLaser
TypeMonochrome
Maximum Print Resolution600 x 600 dpi
Print Resolution600 x 600 dpi
Copy Resolution600 x 600 dpi
Standard Paper Capacity250 sheets
Maximum Paper SizeA4
FunctionsPrint, Copy, Scan
Print Speed16 ppm
Copy Speed16 cpm
Scan Resolution600 x 600 dpi
Operating System CompatibilityWindows
InterfaceUSB 2.0

Related product manuals