CHAPTER 13 TROUBLESHOOTING
COPYRIGHT
©
2002 CANON INC. 2000 CANON iR1600/iR2000 REV.1 JAN. 2002
13-73
5.3 Service Mode Menus
The initial settings are boldfaced.
F13-503-01
#1 SSSW : do not change except SW33; the rest are not used.
#2 MENU : do not change; it is not used.
#3 Numerical Param. : Do not change except 056 through 061; the rest are
not used.
#4 : do not change; it is not used.
#5 TYPE : when a country/region is selected (indicated on the display), the
settings related to items #1 SSSW, #3 Numeric Param, and user data will
collectively be set.
service data
#1 SSSW
(service soft switch setting)
#2 MENU
(menu switch setting)
#3 NUMERIC Param.
(numerical parameters setting)
056 :
057 :
058 :
059 :
060 :
061 :
101
103
201
203
0
0
total 1 indication
total (L) indication
copy (total 1) indication
copy (L) indication
no indication
no indication
Initial setting Remarks
not used
#4A SPECIAL not used
#4B NCU
(NCU setting)
#5 TYPE
(type setting)
not used
#4C ISDN not used
SW33 00000000 counter-related