2 Parameters
2.2 List of parameters
SINAMICS G130/G150
112 List Manual (LH2), 04/2014, A5E03263479A
Dependency: Refer to: p0212
Note: This parameter is only effective for chassis power units with 3 AC line connection and line contactors.
PDS: Power unit Data Set
Bit field: Bit Signal name 1 signal 0 signal FP
00 PDS0 pre-charging/line contactor control
output
High Low -
01 PDS0 pre-charging/line contactor feedback
signal input
High Low -
02 PDS0 bypass contactor control output High Low -
03 PDS0 bypass contactor feedback signal
input
High Low -
04 PDS1 pre-charging/line contactor control
output
High Low -
05 PDS1 pre-charging/line contactor feedback
signal input
High Low -
06 PDS1 bypass contactor control output High Low -
07 PDS1 bypass contactor feedback signal
input
High Low -
08 PDS2 pre-charging/line contactor control
output
High Low -
09 PDS2 pre-charging/line contactor feedback
signal input
High Low -
10 PDS2 bypass contactor control output High Low -
11 PDS2 bypass contactor feedback signal
input
High Low -
12 PDS3 pre-charging/line contactor control
output
High Low -
13 PDS3 pre-charging/line contactor feedback
signal input
High Low -
14 PDS3 bypass contactor control output High Low -
15 PDS3 bypass contactor feedback signal
input
High Low -
16 PDS4 pre-charging/line contactor control
output
High Low -
17 PDS4 pre-charging/line contactor feedback
signal input
High Low -
18 PDS4 bypass contactor control output High Low -
19 PDS4 bypass contactor feedback signal
input
High Low -
20 PDS5 pre-charging/line contactor control
output
High Low -
21 PDS5 pre-charging/line contactor feedback
signal input
High Low -
22 PDS5 bypass contactor control output High Low -
23 PDS5 bypass contactor feedback signal
input
High Low -
24 PDS6 pre-charging/line contactor control
output
High Low -
25 PDS6 pre-charging/line contactor feedback
signal input
High Low -
26 PDS6 bypass contactor control output High Low -
27 PDS6 bypass contactor feedback signal
input
High Low -
28 PDS7 pre-charging/line contactor control
output
High Low -
29 PDS7 pre-charging/line contactor feedback
signal input
High Low -
30 PDS7 bypass contactor control output High Low -
31 PDS7 bypass contactor feedback signal
input
High Low -

Table of Contents

Other manuals for Siemens SINAMICS G150