2 Parameters
2.2 List of parameters
SINAMICS G130/G150
968 List Manual (LH2), 04/2014, A5E03263479A
Description: Displays the memory usage for each drive object as reference value.
Index: [0] = Fast Memory 1
[1] = Fast Memory 2
[2] = Fast Memory 3
[3] = Fast Memory 4
[4] = Heap
Description: Displays the memory usage of an OA application.
Index: [0] = Fast Memory 1
[1] = Fast Memory 2
[2] = Fast Memory 3
[3] = Fast Memory 4
[4] = Heap
Description: Diagnostics parameter to display additional information for internal software errors.
Note: Only for internal Siemens troubleshooting.
Description: Sets the safety communication clock cycle with which the TM54F communicates with a drive.
The communication clock cycle must correspond to the safety monitoring clock cycle of the drive.
Presently, the TM54F only supports one communication clock cycle for all drives.
This is entered into P10000[0].
Index: [0] = Drive 1
[1] = Drive 2
[2] = Drive 3
[3] = Drive 4
r9992[0...4] Memory usage drive object reference value / Mem_use DO ref val
CU_G130_DP,
CU_G130_PN,
CU_G150_DP,
CU_G150_PN
Can be changed: - Calculated: - Access level: 4
Data type: Unsigned32 Dyn. index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
r9993[0...4] Memory usage OA application / Mem_use OA
CU_G130_DP,
CU_G130_PN,
CU_G150_DP,
CU_G150_PN
Can be changed: - Calculated: - Access level: 4
Data type: Unsigned32 Dyn. index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
r9999[0...99] Software error internal supplementary diagnostics / SW_err int diag
CU_G130_DP,
CU_G130_PN,
CU_G150_DP,
CU_G150_PN
Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dyn. index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
p10000[0...5] SI TM54F communication clock cycle / TM54F comm_cycle
TM54F_MA,
TM54F_SL
Can be changed: C2(95) Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: - Func. diagram: -
P-Group: Safety Integrated Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0.00000 [ms] 25.00000 [ms] [0] 12.00000 [ms]
[1...5] 0.00000 [ms]