2 Parameters
2.2 List of parameters
SINAMICS G130/G150
826 List Manual (LH2), 04/2014, A5E03263479A
Description: Displays the active station name for the onboard PROFINET interface on the Control Unit.
Description: Displays the active IP address for the onboard PROFINET interface on the Control Unit.
Description: Displays the active default gateway for the onboard PROFINET interface on the Control Unit.
Description: Displays the active subnet mask for the onboard PROFINET interface on the Control Unit.
Description: Displays the active DHCP mode for the onboard PROFINET interface on the Control Unit.
Notice: When the DHCP mode is active (parameter value greater than 0), PROFINET communication via this interface is no
longer possible! However, the interface can be used for commissioning tool such as STARTER or SCOUT.
Note: If value = 0:
DHCP deactivated.
If value = 2:
DHCP activated. The MAC address of this interface is used for client identification.
If value = 3:
DHCP activated. The station name of this interface is used for client identification.
r8930[0...239] PN Name of Station active / PN Name Stat act
CU_G130_PN,
CU_G150_PN
Can be changed: - Calculated: - Access level: 3
Data type: Unsigned8 Dyn. index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
r8931[0...3] PN IP Address of Station active / PN IP of Stat act
CU_G130_PN,
CU_G150_PN
Can be changed: - Calculated: - Access level: 3
Data type: Unsigned8 Dyn. index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 255 -
r8932[0...3] PN Default Gateway of Station active / PN Def Gateway act
CU_G130_PN,
CU_G150_PN
Can be changed: - Calculated: - Access level: 3
Data type: Unsigned8 Dyn. index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 255 -
r8933[0...3] PN Subnet Mask of Station active / PN Subnet Mask act
CU_G130_PN,
CU_G150_PN
Can be changed: - Calculated: - Access level: 3
Data type: Unsigned8 Dyn. index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 255 -
r8934 PN DHCP Mode active / PN DHCP Mode act
CU_G130_PN,
CU_G150_PN
Can be changed: - Calculated: - Access level: 3
Data type: Unsigned8 Dyn. index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 255 -