SINAMICS G130/G150
List Manual (LH2), 04/2014, A5E03263479A
143
2 Parameters
2.2 List of parameters
Description: Displays the total cable resistance between Motor Module and motor, as well as the internal converter resistance.
Dependency: Refer to: r0238, p0352
Description: Displays the rated motor stator resistance at rated temperature (total of p0625 and p0627).
Dependency: Refer to: p0627
Note: The parameter is not used for synchronous motors (p0300 = 2xx).
Description: Displays the rotor/secondary section resistance of the motor for the ambient temperature p0625.
For separately-excited synchronous motors:
Displays the damping resistance in the rotor direction (d-axis).
Dependency: Refer to: p0625
Note: The parameter is not used for synchronous motors (p0300 = 2xx).
Description: Displays the damping resistance of the separately-excited synchronous motor quadrature to the rotor direction (q
axis).
Description: Displays the nominal rotor / secondary section resistance of the motor at the rated temperature.
r0372[0...n] Cable resistance / Mot R_cable
VECTOR_G Can be changed: - Calculated: - Access level: 4
Data type: FloatingPoint32 Dyn. index: MDS, p0130 Func. diagram: -
P-Group: Motor Units group: 16_1 Unit selection: p0349
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- [ohm] - [ohm] - [ohm]
r0373[0...n] Motor rated stator resistance / Mot R_stator rated
VECTOR_G Can be changed: - Calculated: - Access level: 4
Data type: FloatingPoint32 Dyn. index: MDS, p0130 Func. diagram: -
P-Group: Motor Units group: 16_1 Unit selection: p0349
Not for motor type: PEM, REL, FEM Scaling: - Expert list: 1
Min Max Factory setting
- [ohm] - [ohm] - [ohm]
r0374[0...n] Motor rotor resistance cold / damping resistance d axis / Mot R_r cold/R_D d
VECTOR_G Can be changed: - Calculated: - Access level: 4
Data type: FloatingPoint32 Dyn. index: MDS, p0130 Func. diagram: -
P-Group: Motor Units group: 16_1 Unit selection: p0349
Not for motor type: PEM, REL Scaling: - Expert list: 1
Min Max Factory setting
- [ohm] - [ohm] - [ohm]
r0375[0...n] Motor damping resistance q axis / Mot R_damp q
VECTOR_G Can be changed: - Calculated: - Access level: 4
Data type: FloatingPoint32 Dyn. index: MDS, p0130 Func. diagram: -
P-Group: Motor Units group: 16_1 Unit selection: p0349
Not for motor type: ASM, PEM, REL Scaling: - Expert list: 1
Min Max Factory setting
- [ohm] - [ohm] - [ohm]
r0376[0...n] Rated motor rotor resistance / Mot rated R_rotor
VECTOR_G Can be changed: - Calculated: - Access level: 4
Data type: FloatingPoint32 Dyn. index: MDS, p0130 Func. diagram: -
P-Group: Motor Units group: 16_1 Unit selection: p0349
Not for motor type: PEM, REL, FEM Scaling: - Expert list: 1
Min Max Factory setting
- [ohm] - [ohm] - [ohm]